| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/22/2007 | ROOF NAILING | Approved | IVRS - Inspection :* 1) A-17 IS A 3 PT BEARING TRUSS. YOU HAVE A SINGLE TOP PLATE-ADD ANOTHER PIECE OF PLATE STUD TO STUD THEN SHIM, BEFORE LOADING TILE |
|
| 08/21/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSED 1 ROW EAST SIDE GARAGE AND 1 SHEET CENTER EAST SIDE. MARKED IN BLACK CRAYON 2) NAIL BLOCKING PANELS AT BATH THRU ROOF 3) SHIM 2 PLY A18 TRUSS AT 2 X 6 BEARING WALL AT BATH 4) SHIM TRIMMERS AS NECESSARY TO OBTAIN BEARING ON HEADERS |