Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/07/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 11/05/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) INSTALL 2 X 6 FLAT TOP AND BOTTOM AND SCAB OVER SEAM AS LONG AS POSSIBLE 2) REPAIR DUCT METAL |
|
| 10/30/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) WATER HEATER T & P LINE HAS REVERSE PITCH 2) WATER HEATER T & P LINE MUST EXHAUST DOWN 3) POST TENSION CABLE POCKETS NOT SEALED 4) SEAL HOLE IN GARAGE CEILING WITH 5/8" TYPE X DRYWALL 5) BEARING WALL BEARING STUD CUT/NOTCHED GREATER THAN 25 PERCENT FOR INSTALL OF RANGE HOOD-REPLACE STUD 6) NO RANGE ANTI-TILT 7) NO ACCESS TO ATTIC FURNACE 8) RANGE HOOD DUCT MUST BE 26 GAUGE METAL NOT TAPE |