Permit: T07CM02305

Parcel: 140552940

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
08/29/2007 FRAMING Approved IVRS - Inspection :*
08/23/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVE
2. FIRE BLOCK CHASE IN GARAGE
3. SHEAR WITHOUT BLOCKED OR NAILED ABOVE TRUSS IN GARAGE
4. FIRESTOP SECOND FLOOR TUB PENETRATIONS & AC LINES
5. WEDGE ANCHORS NOT ALLOWED ON EXTERIORS SHEAR WALLS
6. WATER HEATER CABINET MUST BE 24" WIDE FINISHED
7. FIRESTOP REQUIRES 2 LAYERS 1/2" OSB
08/20/2007 FRAMING Not ready for Inspection IVRS - Inspection :*