Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/09/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* RECEIVED CK#35458 FOR $108.00 |
|
| 09/07/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. TIGHTEN LOOSE LOCKNUTS 2. BOXES MORE THAN 1/4" NEED AN APPROVED EXTENDER RING 3. PANEL SCHEDULE TO BE AS PER 408.4 NO ABBREVIATIONS 4. FINISH VDV CABLING 5. GROUNDING EQUIPMENT CONDUCTOR TO BE GREEN OR BARE ENTIRE LENGTH 250.119 6. ONLY ONE CONDUCTOR PER LUG TERMINATION 7. MAINTENANCE RECEPTACLE TO BE WITHIN 25' -- 210.63 |
|
| 09/06/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* |
|
| 08/31/2007 | ELECTRIC - FINAL | Not ready for Inspection | IVRS - Inspection :* |