Permit: T07CM02292

Parcel: 141352170

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02292

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/21/2007 FRAMING Approved IVRS - Inspection :*
08/20/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FILL ALL NAIL HOLES IN JOIST HANGER ABOVE FRONT DOOR
2) OSB NEEDED IN FLOOR TRUSSES ABOVE KITCHEN BEARING WALL PER 303 DETAIL
3) BLOCK RIM JOIST UNDER BEARING OF RAFTER GIRDER TO FOUNDATION
4) UFER NEEDS TO BE CONNECTED TO PANEL
5) BANG PLATES NEEDED OVER 3" ABS IN GARAGE
6) 2ND FLOOR FLOODED UNABLE TO DO ABS TEST
7) SUPPORT ABS IN GARAGE MAX 4'
8) SUPPORT ABS 2" IN FLOOR TRUSSES