Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02286
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/05/2007 | FRAMING | Approved | IVRS - Inspection :* | |
09/04/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 X 6'S NEEDED IN GARAGE UNDER BEAM 2) DRAFT STOP TUBS 3) SEAL TAR PAPER RIPS 2ND FLOOR MASTER BATH 4) NO PRESSURE POTABLE WATER 5) DRAFT STOP MAIN TRUNK LINE |
|
08/31/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 2 X 6 MEMBERS NEEDED IN GARAGE UNDER BEAM 2) PROPER FHA STRAP WITH 16D, 8 EACH SIDE OF NOTCHE IN TOP PLATE KITCHEN WALL 3) DWV TEST 4) BANG PLATE NEEDED MAIN FLOOR BATH TOP PLATES GARAGE/HOUSE WALL 5) NO PRESSURE POTABLE WATER 6) DRAFT STOP TUBS 7) DRAFT STOP MAIN SUPPLY THROUGH FLOOR 8) SEAL TAR PAPER RIPS 2ND FLOOR BATH |
|
08/30/2007 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |