Date Description Inspector Results Comments
08/23/2007 FRAMING Approved IVRS - Inspection :*
08/22/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ENGINEER FIX ON HOLE IN CEMENT UNDER STAIRS-OK
2) SOLID BEARING UNDER 2 PLY RAFTER GIRDER WEST END OF 2ND FLOOR
3) FINISH STUCCO MESH AT FRONT OF HOUSE AND WEST END OF GARAGE, AND NORTH END OF HOUSE
4) SLOPE ON 3" ABS AT BACK OF SOUTH GARAGE
08/14/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) INSIDE CORNERS NEEDED FOR GYP SUM SHEARWALLS
2) MTT 2 B NEEDED NORTH END KITCHEN SHEARWALL
3) DRAFT STOP UNDER TUBS
4) FINISH STUCCO AT EAST SIDE
5) BANG PLATE NEEDED SOUTH WALL TOP PLATE
6) LARGER FHA STRAPS OVER NOTCH INTERIOR WALL FOR DRAFT HOOD DUCT
7) BLOCK 3 SIDES OF DUCT IN FOYER
8) FIRST FLOOR COMPLETE
9) STOPPED INSPECTION