Permit: T07CM02276

Parcel: 141351320

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/01/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/20/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING (2) 2 X 12 AT FRONT OF HOUSE AT BEDROOM WITH POST
2) WRONG HEADER AT FRONT BEDROOM NEEDS TO BE 2 X 8 PER PLAN
3) NEED COIL STRAP AND BLOCKING PER DETAIL 533 NAIL BLOCKING THRU SHEATHING
4) NNED TRUSS DRAWINGS ON SITE
5) PROVIDE RETRO AT FRONT OF HOUSE MISSED AT SHEARWALL