Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T07CM02243
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/17/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* RECEIVED (2) IN HOUSE BACKFLOW CERTIFICATIONS |
|
03/12/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SUPPORT WATER & DRAIN AT DIPPER WELL 2. COMPLETE DRAIN FOR ICE BIN AT SODA DISPENSOR WITH APPROVED MATERIAL NOTE: PVC REQUIRES PRIMER THEN GLUE 3. COMPLETE SODA DISPENSER WATER SUPPLY |
|
03/10/2008 | PLUMBING - FINAL | Not ready for Inspection | REMOVE ALL STUFF BLOCKING SINKS FILL ALL SINKS W/WATER FOR TEST NO FERROUS NIPPLES ALLOWED ON COPPER WATER SYSTEM VENT TERMINATIONS SHALL BE PROTECTED FROM UV ALL EQUIPMENT SHALL BE INSTALLED FOR FINAL PROVIDE LADDER FOR ABV CEILING INSPECTION MAKE ALL CLEANOUTS ACCESSIBLE AND WATER TIGHT BACKFLOW CERTS GRATES MISSING GARDEN HOSE REQUIRES VAC BREAKER *LIST NOT COMPLETE |