| 09/27/2007 | REINFORCED MASONRY PRE-GROUT | Approved | IVRS - Inspection :* | |
| 09/12/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) 2ND LIFT OK FOR ENTRY COLUMNS, PORCH COLUMNS AND EAST PORCH WALL |
|
| 08/29/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* 1) AT REAR PATIO STEPS OK |
|
| 08/23/2007 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* DETAIL 106 TOP OFF DETAIL 107 3' LIFT ONLY DETAIL 102 REAR 4' LIFT ONLY COLUMNS DETAIL 103 TOP OFF |