Permit: T07CM02205

Parcel: 122174330


Addresses:

3250 E PIMA ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/20/2007 FRAMING Approved IVRS - Inspection :*
12/19/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUND WIRE REQUIRED FOR EACH SWITCH
2) SPLICE CAPS OR WIRE NUTS REQUIRED ON GROUND WIRES
3) CLOSET LIGHTS MUST BE MINIMUM 6" CLEAR FROM VERTICAL LINE AT FRONT OF SHELF
4) NO T/P RELIEF LINE
5) NEED 12" CLEAR PEX TO CAN LIGHTS
6) NAIL STOP ABS AT BOTTOM PLATE AND TOP PLATES AS REQUIRED THRU OUT
7) GAS TEST AT 1 1/2 POUNDS
8) SMOKE DETECTORS ARE TO BE LOCATED AT LEAST 6" FROM A CORNER
9) THREE BOXES HAVE NO WIRE