Permit: T07CM02167

Parcel: 141351310

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02167

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/15/2007 FRAMING Approved IVRS - Inspection :*
08/14/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) HTT22 NEEDED BOTH ENDS OF MAIN FLOOR BATHROOM SHEARWALL
2) CORNER BACKER FOR GYP SUM SHEARWALL NORTH WEST INSIDE CORNER OF DINING ROOM
3) ANOTHER TRIMMER NEEDED UNDER 2-2 X 12 HEADER TO UPSTAIRS ON EAST EXTERIOR WALL
4) TRUSS FIX FOR RAFTER FIX
5) BLOCK UNDER TRIMMERS FOR RAFTER GIRDERS AT RIM THROUGHOUT
08/13/2007 FRAMING Not ready for Inspection IVRS - Inspection :*
07/24/2007 FRAMING Partial Approval IVRS - Inspection :*