Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - FINAL
Permit Number - T07CM02136
Inspection Description - MECHANICAL - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/19/2007 | MECHANICAL - FINAL | Approved | IVRS - Inspection :* | |
10/17/2007 | MECHANICAL - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* HORIZ. UNIT IN ATTIC NOT LEVEL CAUSING WATER TO RUN OUT OF PAN INTO DUCT WORK. 1. RE-LEVEL UNIT 2. REPLACE ALL WET INSULATION AT SUPPLY DUCT 3. FLUE PIPE TOO CLOSE TO COMBUSTIBLE MATERIAL AT ROOF LINE 4. PRIMER WAS NOT USED ON ALL PVC CONDENSATE JOINTS SOME JOINTS NO GLUE. REPAIR CONDENSATE PIPING USING PRIMER AND GLUE APPROVED FOR PVC PIPE ON ALL JOINTS. |