Permit: T07CM02136

Parcel: 140265020

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
10/19/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
10/17/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
HORIZ. UNIT IN ATTIC NOT LEVEL CAUSING WATER TO RUN OUT OF PAN INTO DUCT WORK.

1. RE-LEVEL UNIT
2. REPLACE ALL WET INSULATION AT SUPPLY DUCT
3. FLUE PIPE TOO CLOSE TO COMBUSTIBLE MATERIAL AT ROOF LINE
4. PRIMER WAS NOT USED ON ALL PVC CONDENSATE JOINTS SOME JOINTS NO GLUE. REPAIR CONDENSATE PIPING USING PRIMER AND GLUE APPROVED FOR PVC PIPE ON ALL JOINTS.