Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02136

Parcel: 140265020

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Permit Number - T07CM02136

Inspection Description - MECHANICAL - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/19/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
10/17/2007 MECHANICAL - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
HORIZ. UNIT IN ATTIC NOT LEVEL CAUSING WATER TO RUN OUT OF PAN INTO DUCT WORK.

1. RE-LEVEL UNIT
2. REPLACE ALL WET INSULATION AT SUPPLY DUCT
3. FLUE PIPE TOO CLOSE TO COMBUSTIBLE MATERIAL AT ROOF LINE
4. PRIMER WAS NOT USED ON ALL PVC CONDENSATE JOINTS SOME JOINTS NO GLUE. REPAIR CONDENSATE PIPING USING PRIMER AND GLUE APPROVED FOR PVC PIPE ON ALL JOINTS.