Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/20/2007 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) PLUMBING FINAL OK 2) OK FOR C OF O S.T.O.I. |
|
| 11/19/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. IT APPEARS THAT THE PLUMBER WET VENTED THE SINK ABOVE THE AIR GAP FITTING. THIS IS NOT PER CODE, AND IS NOT INSTALLED PER PLAN. 2. WET VENTED SECTION TO BE ONE PIPE SIZE LARGER THAN MINIMUM WASTE SIZE OF UPPER FIXTURE. |
|
| 11/14/2007 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* EXPOSE COVERED CLEANOUTS NO VALVES ALLOWED DNSTRM OF AVB AT BED PAN WASHER |
|
| 11/08/2007 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* GAS CARD LEFT SW GAS 889-1888 |