Permit: T07CM02112

Parcel: 141350070

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02112

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/09/2007 FRAMING Approved IVRS - Inspection :*
07/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ANCHOR BOLT NEEDED IN SOLE PLATE NORTH END OF OVERHEAD DOOR WALL
2) 2" WASHER NEEDED ON ANCHOR BOLT FRONT SHEARWALL SOUTH END
3) VACUUM BREAKER NEEDED AT HOSE BIB
4) NAIL PROTECT WATER SUPPLY LINE IN GARAGE AT TOP PLATES
5) BRACE WATER SUPPLY LINE WHERE IT COMES INTO GARAGE
6) NAIL PROTECT ABS IN FRONT BATHROOM
7) MINIMUM 12" CLEARANCE ON PEX LINES TO RECESSED LIGHTS
8) NAIL PROTECT WATER LINE TO BACK OF HOUSE AT TOP PLATES BACK BEDROOM
9) NAIL PROTECT WIRE IN 2 X 4 WALL BACK BEDROOM WEST WALL