Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM02112
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/09/2007 | FRAMING | Approved | IVRS - Inspection :* | |
07/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ANCHOR BOLT NEEDED IN SOLE PLATE NORTH END OF OVERHEAD DOOR WALL 2) 2" WASHER NEEDED ON ANCHOR BOLT FRONT SHEARWALL SOUTH END 3) VACUUM BREAKER NEEDED AT HOSE BIB 4) NAIL PROTECT WATER SUPPLY LINE IN GARAGE AT TOP PLATES 5) BRACE WATER SUPPLY LINE WHERE IT COMES INTO GARAGE 6) NAIL PROTECT ABS IN FRONT BATHROOM 7) MINIMUM 12" CLEARANCE ON PEX LINES TO RECESSED LIGHTS 8) NAIL PROTECT WATER LINE TO BACK OF HOUSE AT TOP PLATES BACK BEDROOM 9) NAIL PROTECT WIRE IN 2 X 4 WALL BACK BEDROOM WEST WALL |