Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02109

Parcel: 141352270

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T07CM02109

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
08/02/2007 FRAMING Approved IVRS - Inspection :*
08/01/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NAIL OFF 2ND FLOOR NORTH EAST SHEARWALL SOLE PLATE TO SPECS
2) SEAL FIRESTOP 2ND FLOOR TRUNK LINE IN DUCT CHASE AT CEILING
3) FINISH MESH UNDER ELECTRIC PANEL
4) MINIMUM 12" CLEARANCE ON PEX LINE TO RECESSED CAN ABOVE FOYER
5) BLOCK DUCK MINIMUM 3 SIDES IN LIVING ROOM