Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/05/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED BLOCKING PER DETAIL 4A5.1 2) NEED PA18 STRAPS PER DETAIL 7A5.1 AND 6A5.1 3) NEED TRUSS DRAWINGS ON SITE WITH CITY APPROVAL FOR REVIEW |