Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02093
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 06/26/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) STRAP PLATE/GLUE LAM AT GARAGE FRONT 2) X BRACE REAR MAIN TRUSSES, RUN 2 X AT DIAGONAL ON WEBS 3) MISSED NAILING ON ROOF 4) LATH BACKING FRONT GABLE 5) NAILS IN EAST P.A., TOE NAIL WITH SINKERS DBL SHEAR 6) 16D ARE IN JOINT OF STUD |