Inspection History: FRAMING

Permit Number - T07CM02092

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
07/12/2007 FRAMING Approved IVRS - Inspection :*
07/06/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) TILE ALL DUCTS TOGETHER-INCOMPLETE, NOT AN ATTIC FURNACE
2) BLOCK ALL MECH
3) NEED FIRE STOP AT RANGE DUCT 1
4) MST BATHROOM NEEDS VERT. SURROUND BACKING-SECURE ALL TUB SURROUNDS
5) FRONT HIP HANGERS
6) REMOVE SURROUND AT GARAGE WALL-VERIFY H.D.