Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - CABLE DROP
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/28/2007 | ELECTRIC - CABLE DROP | Approved | IVRS - Inspection :* | |
| 10/04/2007 | ELECTRIC - CABLE DROP | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SERVICE OK BUT YOUR PLAN CALLS FOR UNDERGROUND ELECTRIC SERVICE. YOU MUST OBTAIN A WAIVER FROM CITY OF TUCSON TO USE AN OVERHEAD ELECTRIC SERVICE |
|
| 10/02/2007 | ELECTRIC - CABLE DROP | Denied | IVRS - Inspection : See detailed listing on site.| 999* PER D WITT: 1) USE HTT22 HD'S EAST SIDE GARAGE WITH EPOXY BOLTS 2) PA STRAPS WEST SIDE GARAGE OK 3) HOUSE FULLY SHEARED SO REMAINING PA STRAPS NOT REQUIRED 4) OK TO DRY IN AND WRAP 5) UFER MUST BE CAD WELDED OR USE AN APPROVED NON REVERSEIBLE COUPLING |