Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
Permit Number - T07CM02084
Inspection Description - SHEET ROCK NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/09/2007 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 08/08/2007 | SHEET ROCK NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEARWALLS (3) NEED TO BE NAILED 4" ON CENTER, THE COMPLETE HEIGHT OF WALL WHICH IS SUPPOSE TO BE 10' 2) NAILING ON BOTTOM SHEAR WALL PLATE #2 NEEDS TO BE 7" ON CENTER |
|
| 08/06/2007 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* OK TO CONTINUE INSPECTED SHEETROCK IN GARAGE CEILING TRUSSES - OK |