Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02084
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/30/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) TRUSS ISSUES HAVE BEEN CORRECTED |
|
| 07/19/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* ITEMS #1 & #2 NOT MET AT THIS TIME, WILL FOR PAPERWORK AT INTERMEDIATES |
|
| 07/18/2007 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER SUPER |
|
| 07/16/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ENGINEER ON TRUSS SF340T FOR FIX ON GUSSES PLATE 2) NEED TRUSS REPAIR FOR TRUSS SF10A-BROKEN BOTTOM CHORD 3) SHEAR TRANSFER AT BEDROOM #4 CLOSET NOT PER DETAIL (1 1/2 GAP BETWEEN BLOCKING AND TOP PLATES BETWEEN BLOCKING AND TOP PLATES 4) H2.5 AT GARGE TRUSSES MISSING NAILING 5) FLIP H.25 AT PATIO PORCH 6) NAILING AT HOLDOWN STUD MISSING NAILS 7) OK TO DRY ROOF IN |