Permit: T07CM02070

Parcel: 129132820


Addresses:

726 E 34TH ST

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
05/23/2010 BUILDING - FINAL Approved IVRS - Inspection :*
04/28/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) CHECK ELECTRIC OPEN GROUND THRU-OUT-ARC FAULT PROTECTION REQUIRED IN BEDROOM OUTLET, SWITCHES AND SMOKE ALARAMS
2) SEDIMENT TRAP MISSING AT FURNACE AND WATER HEATER
3) SHALL BE 6" FROM COMBUSTIBLE OR 1" IF IT'S DBL WALL
4) EXTEND BATH VENT 12" ABOVE ROOF
5) PTR LINE MISSING AT WATER HEATER
6) VACUUM BREAKERS REQUIRED AT EXT. HOSE BIBS
7) BUBBLE COVERS REQUIRED ON EXT. OUTLETS
8) SECURE COOLER ELECTRIC BOX TO ROOF
9) SECURE CORD TO COOLER