Inspection History Details
Permit: T07CM02039
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/12/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
| 09/10/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. INSULATION NOT INSTALLED PER PLAN 2. DWV PIPING WILL BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS 3. ALL VERTICAL DWV WILL BE SUPPORTED AT EACH FLOOR WITH MID-STORY GUIDES |
|
| 09/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
| 09/04/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | CANCEL PER JASON | |
| 08/31/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |