Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T07CM02039


Addresses:

4585 N ORACLE RD


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T07CM02039

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
09/12/2007 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
OK TO COVER ALL AREAS
09/10/2007 PLUMBING - INTERMEDIATE Not ready for Inspection 1. INSULATION NOT INSTALLED PER PLAN
2. DWV PIPING WILL BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS
3. ALL VERTICAL DWV WILL BE SUPPORTED AT EACH FLOOR WITH MID-STORY GUIDES
09/05/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*
09/04/2007 PLUMBING - INTERMEDIATE Not ready for Inspection CANCEL PER JASON
08/31/2007 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*