Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM02039
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* OK TO COVER ALL AREAS |
|
09/10/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | 1. INSULATION NOT INSTALLED PER PLAN 2. DWV PIPING WILL BE SUPPORTED AT EACH CHANGE OF DIRECTION OR ELEVATION, AND AT THE END OF BRANCHES, THEN NO MORE THAN FOUR FEET BETWEEN HANGERS 3. ALL VERTICAL DWV WILL BE SUPPORTED AT EACH FLOOR WITH MID-STORY GUIDES |
|
09/05/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* | |
09/04/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | CANCEL PER JASON | |
08/31/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |