Permit: T07CM02029

Parcel: 141096950

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/12/2007 FRAMING Approved IVRS - Inspection :*
1) OK TO REPLACE CONCRETE
07/23/2007 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO INSULATE AND DRYWALL
2) POST TENSION FLOOR HAS BEEN CUT AND PLUMBING RELOCATED-REMOVE CONCRETE
3) PROVIDE CITY APPROVED ENGINEERING REPAIR
4) REPAIR FOR CITY/ENGINEER INSPECTION
07/17/2007 FRAMING Denied IVRS - Inspection :
Work is not complete enough to inspect.| 950*
1) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES
2) LATHE NOT COMPLETE
3) NO DWV WATER TEST
4) FURNACE B-VENT NOT CONNECTED TO UNIT PER INSTALLATION MANUAL
5) FURNACE GAS VENT HAS REVERSE PITCH
6) A/C DUCT BOOT NOT INSTALLED
7) BLOCK DUCT BOOTS 3 SIDES
8) HALL TOILET MUST HAVE 15" CLEARANCE TO TUB
9) STOPPED INSPECTION-TOO MANY ITEMS