Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/12/2007 | FRAMING | Approved | IVRS - Inspection :* 1) OK TO REPLACE CONCRETE |
|
07/23/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OK TO INSULATE AND DRYWALL 2) POST TENSION FLOOR HAS BEEN CUT AND PLUMBING RELOCATED-REMOVE CONCRETE 3) PROVIDE CITY APPROVED ENGINEERING REPAIR 4) REPAIR FOR CITY/ENGINEER INSPECTION |
|
07/17/2007 | FRAMING | Denied | IVRS - Inspection : Work is not complete enough to inspect.| 950* 1) OUTSIDE HOSE BIBS REQUIRE ANTI-SIPHON VALVES 2) LATHE NOT COMPLETE 3) NO DWV WATER TEST 4) FURNACE B-VENT NOT CONNECTED TO UNIT PER INSTALLATION MANUAL 5) FURNACE GAS VENT HAS REVERSE PITCH 6) A/C DUCT BOOT NOT INSTALLED 7) BLOCK DUCT BOOTS 3 SIDES 8) HALL TOILET MUST HAVE 15" CLEARANCE TO TUB 9) STOPPED INSPECTION-TOO MANY ITEMS |