Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/11/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 07/09/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) B-VENT NEEDS TO BE DBL WALL WHEN GOING THRU ROOF AND EXTEND 12" OUTSIDE OF ROOF 2) NEED HIGH/LOW COMBUSTION AT WATER HEATER |
|
| 06/28/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) EXISTING SINK PLUMBING NEED TO BE VENTED WITH 2" VTR 2) EXTEND VTR THRU ROOF 3) EXTEND B-VENT THRU ROOF 4) ALL COVER PLATES SHOULD BE ON OUTLET BOXES 5) NEED TO COVER CEILING AT LAUNDRY ROOM 6) PAINT ALL ABS VTR ON ROOF 7) LANDIN G AT SIDE DOOR MUST BE PERMANENT |
|
| 06/26/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE ARC FAULT BREAKERS AT BEDROOM CIRCUITS 2) SECURE GFCI'S AT EXTERIOR MAIN PANEL 3) PROVIDE LANDING AT EXTERIOR DOOR OFF BEDROOM |