Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM02003
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/11/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
07/10/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ST6224 STRAP NEEDED PER PLAN SD/527 AT TOP PLATES 2) CS16 X 24 NEEDED FROM BOTTOM CHORD TO TOP PLATE AT R5 PER FLOOR FRAMING PLAN ABOVE FRONT DOOR 3) PROTECT ABS PIPES AT EXTERIOR BOTTOM PLATE 4) NAIL MAS STRAP WEST OF FRONT DOOR PORCH 5) LTP4 MAX 24" ON CENTER AT GABLE END WALL WEST SIDE OF GARAGE ABOVE SHEARWALL 6) BLOCK SHEARWALL SEAM IN ATTIC 7) NAIL DOWN THROUGH ROOF SHEATHING TO SHEAR WALL IN ATTIC |