Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01999
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/06/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* NOT DONE -- ITEMS 1,2,3, 4, 6, 7, 8, 9, 10 AND 11 FROM PREV. INSP. ON 8/2/07 |
|
| 08/02/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GARAGE TRUSSES, SOME TRUSSES ARE NOT PLUMB 2) SHEAR TRANSFER AT TOP OF WALL GYP=OSB NEED BLOCKS NAILING FOR JOINT GYP BOARD TO OSB 3) DBL STUD BELOW ROOF GIRDER ABOVE GARAGE ALL THE WAY DOWN TO CONCRETE CONTINOUS BETWEEN FLOORS 4) WRONG NAILS IN HANGERS ROOF TRUSSES 5) REAR WALL NAIL 1ST/2ND FLOOR STRAPS (CS) TYPE 6) MISSING WIND BRACE, REAR WALL, 2ND FLOOR 7) H2.5 AT RAFTER TAILS, FRONT 2ND FLOOR BAY WINDOW 8) 93/SD3 NAIL SHEAR BLOCKING PANELS TO ROOF 9) BLOCK AND OR NAIL ALL BLACK MARKS ON ROOF 10) G4 SHEAR 2ND FLOOR EACH END ON SD4 #21, 16 DETAIL REQUIRED 11) 2/SD2 CS20 COIL STRAP EVERY OTHER STUD, 10" LAP ABOVE/BELOW PLATE TO TIE JOINT OF LARGE OSB SHEARWALL FLOOR TO FLOOR |