Permit: T07CM01953

Parcel: 141096490

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
06/21/2007 ROOF NAILING Approved IVRS - Inspection :*
06/20/2007 ROOF NAILING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 10/D-5 REQUIIRES VERTICAL MSTL STRAPS
2) GARAGE FRONT SHEARWALL 5 REQUIRES NAILS AT 3" ON CENTER
3) DIAGONAL BRACES REQUIRE 2-16D EACH END
4) 9/D-3 REQUIRED HTC4 CLIPS
5) SCISSOR TRUSSES REQUIRE 1/2" CLEARANCE TO WALL BELOW AT MID POINTS-PORCH
6) NO LADDER ACCESS TO ROOF
7) NO APPROVED TRUSS DRAWINGS