Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T07CM01953
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2007 | ROOF NAILING | Approved | IVRS - Inspection :* | |
06/20/2007 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 10/D-5 REQUIIRES VERTICAL MSTL STRAPS 2) GARAGE FRONT SHEARWALL 5 REQUIRES NAILS AT 3" ON CENTER 3) DIAGONAL BRACES REQUIRE 2-16D EACH END 4) 9/D-3 REQUIRED HTC4 CLIPS 5) SCISSOR TRUSSES REQUIRE 1/2" CLEARANCE TO WALL BELOW AT MID POINTS-PORCH 6) NO LADDER ACCESS TO ROOF 7) NO APPROVED TRUSS DRAWINGS |