Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T07CM01952
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
06/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PROVIDE 8/D-1 DETAIL FOR GARAGE FRONT 2) RAFTER SPACED MORE THAN 24" ON CENTER OVER FRONT BEDROOM 3) RAFTER NOTCHED MORE THAN 25 PERCENT OVER FRONT BEDROOM 4) ROOF SHEATHING MUST SPAN 3 TRUSSES (2 BAYS) 5) OSB ROOF SHEATHING MUST BE INSTALLED WITH GRAIN PERPENDICULAR TO TRUSSES 6) SOME AREAS OF ROOF NOT NAILED |