Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/24/2007 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* RECEIVED (7) IN-HOUSE BACKFLOW CERTIFICATIONS 1. SHALL TERMINATE WATER HEATER VENT CORRECTLY 2. SUPPORT GAS PIPING ON ROOF 3. WATER HEATER T&P DRAIN SHALL TERMINATE 90 DEG. DOWN AT EXTERIOR |
|
| 10/22/2007 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* SINK DRAIN FOR LAV & HAND SINK & WATER OK |
|
| 10/18/2007 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV WATER TEST TO EXISTING & THRU ROOF OK WATER DISTRIBUTION OK 1. SHALL SUPPORT OVERHEAD VENT IN ATTIC 2. SHALL REROUTE VENT AWAY FROM DEDICATED HEATER PANEL SPACE 3. SHALL INSULATE 8' IN & OUT OF WATER HEATER PIPING. |