Permit: T07CM01910

Parcel: 141185530


Addresses:

9337 E OLD VAIL RD

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
04/25/2008 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
(EXTERIOR CMU)
TOP OUT AT BOTH SIDES CLOSURE WALLS
04/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT WEST & EAST HARD WALLS AT FRONT OF BLDG.
02/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TRASH ENCLOSURE TOP OUT AT 6' OK
NORTH/REAR SITE WALL FROM 4' TO 6' OK
02/27/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
WEST HALF OF REAR SITE WALL TO TOP OUT @ 6' AND EAST HALF FROM 0' TO 4' TRASH ENCLOSURE 0' TO 4' & ENTRY CMU COLUMNS FROM 0' TO 6'8"
02/25/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
MAIN BUILDING TOP OUT @ 27'4"
AND WEST HALF OF REAR SITE WALL FROM 0' TO 4' OK
02/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP LINE A
02/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP LINE C
02/20/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES D/1 TO 3
TOPOUT @ 28' AFF - A/1 TO 3 FROM 20' TO 24' AFF AND
3/A TO C.3 TO 22'8" AFF
02/15/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT
02/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 1/A TO D & D/1
TO 3 AND 3/C.5 TO D FROM 20' TO 24' AFF
02/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES A/1.5 TO 3 AND 3/A TO C.3 FROM 16' TO 20' AFF
02/12/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES D/3 TO 1
1/A TO D, A/1 TO 1.7 FROM 16' TO 20' AFF
02/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINE 3/A.6 TO C.3
FROM 12' TO 16' AFF
02/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 3/C.4 TO D
D/1 TO 3 - 1/A TO D FROM 12' TO 16' AND 3/B.3 TO C.4
FROM 8' TO 12' AND FROM 3/B.6 TO B.8 FROM 9.2 TO 13'2" AFF
02/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES D/2.5 TO 1
1/A TO D - A/1 TO 3 & 3/A TO B.3 --
OK TO GROUT FROM 8' TO 12' AFF
02/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 3/C.5 TO A
AND A/2.5 TO 3 FROM 4' TO 8' AFF AND 3/C.5 TO D & D/3 TO 2.5
FROM 8' TO 12' AFF -- OK TO GROUT
02/05/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU REINFORCEMENT STEEL @ GRID LINES 1/A TO D,
D/1 TO 3, 3/D TO C.4 & A/1 TO 2.4 FROM 4' TO 8' AFF
02/04/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED-RAINED OUT
02/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
BALANCE OF PERIMETER CMU WALLS FROM 0' TO 4'
01/31/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU PERIMETER WALL REINFORCEMENT STEEL @
EAST & NORTH SIDES FROM 0' TO 4' AFF -- OK TO GROUT
01/11/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
EAST & WEST SITE WALLS TOP OUT
01/09/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. WEST SIDE SITE WALL 2ND LIFT
2. EAST SIDE SITE WALL TOP OUT
01/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
RETAINING WALL ONLY