Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/02/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 09/17/2007 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OK MAIN HOUSE ONLY-GARAGE AND STORAGE PENDING REVISIONS |
|
| 09/14/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NO PLANS OR INSPECTION CARD ON SITE 2) ALL GATES LOCKED |
|
| 09/06/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) H2.5 CLIPS SHALL BE FROM TRUSS TO CMU PLATE OR CLIP DBL PLATE TO STUDS AND BOTTOM PLATE TO STUD, HEADERS TO CRIPPLES 2) TIGHTEN NUTS AT BEAM BEARING AT FRONT BEDROOM WINDOW 3) PEX LINES SHALL BE 12" MIN FROM LIGTH CANS 4) REVISE PLAN TO REFLECT AS BUILT IN C.P. STG. |