Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/20/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 08/15/2007 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) TRUSS PROBLEMS FROM LAST INSPECTION |
|
| 08/13/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING GUSSET PLATE 3 PT BEARING TRUSS, NORTH OF FRONT DOOR, SHIM 3 PT 2) TWO NAILS IN WINDBRACE TO PLATE CONNECTION 3) HANGERS FOR REAR HIPS 4) A7A DBL GIRDER, & A6A MISSED BEARING PT. 5) SHEAR CONNECTION FRONT BEDROOM LTP4 AT 48" ON CENTER OR 16D 12" ON CENTER TOE NAIL 6) ONE A35F EACH SIDE OF EACH SHEARWALL GARAGE SHEAR FRONT 7) MISSED NAILING ON ROOF MARKED IN BLACK |