Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T07CM01890
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/23/2011 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* 1) CLOSET FLANGES OK |
|
03/25/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 3502 & 3504 SEWER MODIFICATION TO INCLUDE B.W. VALVE AND VENTING OF SEWER DOWNSTREAM 2) OK TO COVER SUBJECT TO APPROVED PLAN |
|
03/22/2011 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* 1) CLOSET FLANGES TO EXTEND 1/4" ABOVE FINISHED FLOOR FLANGES TO BE SCREWED TO THE FLOOR 2) 2 BACK WATER VALVES INSTALLED. ALL FITTINGS TO OPEN IN THE DIRECTION OF FLOW, ABS MAY NOT BE INSTALLED IN EXPOSED EXTERIOR LOCATION, REQUIRES TRACER WIRE ON VENTS UG. |
|
01/06/2011 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* 1) CALL BACK FOR CLOSET FLANGE 2) PROVIDE APPROVED PLAN FOR YARD WATER |
|
12/21/2010 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* | |
06/04/2010 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |