Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07CM01886
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2007 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* MC TO BE SUPPORTED AS PER 330.30 & 300.11 |
|
| 07/20/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. FINISH #4 OF INSPECTION DATED 6/21/07 2. PLEASE USE QUALIFIED ELECTRICAL PERSONNEL |
|
| 07/16/2007 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. SUPPORT WIRES ARE NEEDED FOR FIXTURES -- 2 ON OPPOSITE CORNERS -- ALSO, ATTACH TO GRID 2 SCREWS ON CENTER OR 4 ON CORNERS 410.16 2. FINISH #4, 5, 6 OF PREVIOUS INSPECTION |
|
| 06/21/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. CORD NOT ALLOWED AS PERMANENT WIRING FOR LIGHTS ALSO, LIGHTS TO BE LISTED FOR CORD & PLUG CONNECTION AREA TO HAVE PERMANENT LIGHTING. 2. LABEL BREAKERS AS PER 408.4 3. BATHROOM RECEPTACLE TO BE GFCI PROTECTED 4. SUPPORT M/C CABLES ABOVE CEILING AS PER CODE 5. FILL UNUSED OPENINGS IN JUNCTION BOXES 6. PLEASE ADD SUITE # TO PERMIT |
|
| 06/20/2007 | ELECTRIC - FINAL | Denied | IVRS - Inspection : There is no access to the site.| 920* CANNOT LOCATE SPACE - NO SUITE # POSTED |