Permit: T07CM01881

Inspection Status: Approved

Inspection History: MECHANICAL - FINAL

Date Description Inspector Results Comments
08/02/2007 MECHANICAL - FINAL Approved IVRS - Inspection :*
07/30/2007 MECHANICAL - FINAL Partial Approval DO NOT MOUNT DISCONNECTS ONTO A SERVICE PANEL.
I.D ROOFTOP UNITS W/SUITE NUMBERS
REMOVE ALL DUCT TAPE EXPOSED OUTSIDE ON REFER LINES
SECURE INSULATION & LINES WITH APPROVED METHODS
SEE BLDG. INSPECTOR FOR TEMP C OF O
07/26/2007 MECHANICAL - FINAL Not ready for Inspection IVRS - Inspection :*
07/25/2007 MECHANICAL - FINAL Partial Approval IVRS - Inspection :*
CAP OFF UNUSED CONDENSATE OUTLETS
PROVIDE BUSHINGS IN FAN COIL KNOCKOUTS TO PROTECT REFER LINES.
OK FOR CEILING TILES.
LEAVE OUT AROUND EACH FAN COIL