Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/08/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* PER MINIMUM STANDARDS FOR EXISTING BLD'S |
|
| 08/03/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. FRONT ENTRANCE MUST BE ACCESSIBLE 2. THRESHOLDS MAY NOT EXCEED 1/2" WITH MAX 1/4" VERTICAL 3. PLACE SIGN @ ENTRANCE "DOOR TO REMAIN UNLOCKED..." |
|
| 07/30/2007 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* PROVIDE PART OF ACCESSIBILITY ROUTE LANDING AND RAMP |
|
| 07/19/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* IN ACCORDANCE WITH THE SECTION 109.3.10 FINAL INSPECTION SHALL BE MADE AFTER ALL WORK REQUIRED BY THE BUILDING PERMIT IS COMPLETED. RESTROOMS ARE NOT IN COMPLIANCE WITH ANSI A117.1.03 REGARDING SECTION 604.2 THE WATER CLOSET SHALL BE LOCATED WITH A WALL THE CENTER LINE OF WC SHALL BE 16" MIN. 18" MAX., LOCATION OF GRAB BARS 604.5 ANSI A117.1 VERIFY AC UNIT INSTALLED UNDER PERMIT ALSO, SIGN IN FRONT OF PARKING SPACE NEEDS TO BE 84" AT THE BOTTOM OF SIGN MEASURED FROM GRADE (HEIGHT) CONTACT ARCHITECT FOR SPECIFIC INFORMATION |