Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/29/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 10/27/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. USE APPROVED HARDWARE WITH DEVICES -- NOT DRYWALL SCREWS 2. A CONNECTOR IS NEEDED AT HOOD 3. TIGHTEN LOOSE FITTING AT WATER HEATER 4. USE TERMINAL ENDS WITH STRANDED CONDUCTORS AT SCREWS 5. WATER HEATER NEED DISCONNECTING MEANS 6. BOXES MORE THAN 1/4" & 1/8" AT SURFACE - 314.20 & 314.21 7. OUTDOOR RECEPTACLES TO BE WEATHERPROOF AS PER 406.8 8. NEED WEATHERPROOF COVER AT MAIN BREAKER |
|
| 09/30/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* RECONNECT INSPECTION ONLY |
|
| 08/29/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* INTERMEDIATE INSPECTION ONLY OK WALLS |