Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T07CM01828

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
11/06/2007 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
10/31/2007 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) OK TO BURY, NEED ANTI SIPHON ON HOSE BIB
2) NEED TO CLEANOUT ALL CELLS THAT ARE TO BE GROUTED
3) MISSING NAILS IN PURLIN STRAPS
4) MISSING MID-SPAN BLOCKING
5) OK TO FINISH OSB ON EAST SIDE
10/19/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK TO CONTINUE TO LAST LIFT
10/03/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) INSPECTED UP TO 16' OK TO CONTINUE TO NEXT LIFT
09/17/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) INSPECTED UP TO 12' OK TO CONTINUE NEXT LIFT
09/11/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK TO GROUT BACK HALF OF HOUSE
2) CONTINUE TO NEXT 4' LIFT AT FRONT OF HOUSE
09/05/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) OK TO CONTINUE TO NEXT LIFT, INSPECTED UP TO 8'
08/31/2007 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) 1ST LIFT OK TO GROUT