Permit: T07CM01818

Parcel: 140280310


Addresses:

2115 E VALENCIA RD

Inspection Status: Approved

Inspection History: MECHANICAL - INTERMEDIATE

Date Description Inspector Results Comments
04/11/2008 MECHANICAL - INTERMEDIATE Approved IVRS - Inspection :*
04/08/2008 MECHANICAL - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. EXHAUST DUCT NOT MECHANICALLY FASTENED (SCREWS) TO FAN
2. PROVIDE CLEANOUTS AT ALL CHANGES OF DIRECTION ON CONDENSATE PIPING PER SPECS
3. INSULATE CONDENSATE PIPING PER SPECS
4. PROVIDE R-5 INSULATION ON DUCT WORK PER MECHANICAL SPECS
5. VERIFY STRAP SUPPORTS ARE CONSISTENT WITH MECHANICAL SPECS