Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T07CM01817
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/01/2008 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
01/25/2008 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OPEN GROUND AT 2 RECEPTACLES AT KITCHEN BAR 2) MISSING EXHAUST FAN AT LAUNDRY ROOM 3) MASTER BEDROOM MISSING RECEPTACLE 4) NEED WATER RECEPTION FOR H20 HEATER 5) BUBBLE COVER NEEDED AT EXT. RECEPTACLES 2 PLACES 6) PAINT VTR STACK ON ROOF 7) CONDENSATE DRAIN NEEDS A 90 DEGREE ELBOW 8) FACE COVER FOR ELECTRIC PANEL BOARD MISSING SCREWS 9) NEED TO SUPPORT ELECTRICAL CONDUIT ON ROOF FROM BRIDGING 10) NEED ANTI-SIPHON ON HOSE BIBS 11) ALL CAN LIGHTS IN KITCHEN MUST BE COMPLETED AND OPERABLE |