Permit: T07CM01809

Parcel: 116181620


Addresses:

1034 W ALAMEDA ST

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
06/12/2007 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
06/11/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WATER CLOSET HAS TO BE MOVED FOR MIN. DISTANCE WILL RE-CHECK WATER TEST
06/05/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) LEAK AT WATER CLOSET
2) OK TO BACKFILL TRENCH CLEANOUT TO HCS CONNECTION
06/01/2007 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) NO 10' WATER TEST
2) 90 DEGREE ELBOW ON 4" LINE NEEDS TO BE LONG RADIUS ON 2-45 DEGREE ELBOW
3) 90 DEGREE ELBOW ON 3" LINE NEEDS TO BE LONG RADIUS ON 2-45 DEGREE ELBOW
4) MISSING TRACER WIRE FROM CLEANOUT TO HCS CONNECTION