Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2007 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 12/07/2007 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH DETAIL A PER REVISION 2 X BLOCKING 8D 6" ON CENTER 2) CHECK SCREWS ALL BRACED PANELS 6" ON CENTER EDGES 12" IN FIELD/2 AB'S PER BRACED PANEL 3) X BRACE GABLE ENDS |