Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T07CM01742
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/05/2007 | FRAMING | Approved | IVRS - Inspection :* | |
07/03/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. FINISH FIREPLACE FRAMING 2. HOLE IN PEX AT KITCHEN SINK 3. NAIL STUDS TO OSB, AT H.D DBL STUDS 4. OVERNOTCHED AT LAV 1ST FLOOR 5. ROMEX HANGING OUT OF WALL KIT, COUNTERTOP CIRCUIT 6. LINE SETS OUT OF WALL 7. NAIL STRINGERS STAIR TO WALL 8. X-BRACE REAR MAIN TRUSSES 9. SHEAR WALL STRAP AT 2ND FLOOR SHEAR WALL |