Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 08/30/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FHA TOP PLATES 2" AND BOTTOM PLATES AT 3" 2) STUD SHOES AT DIRTY ARM 3) OSB WITH 3" ON CENTER 4) MOVE PEX 12" FROM CANS AND SUPPORT VENT 90'S 5) BLOCK DUCT BOOTS ON 3 SIDES 6) SECURE WIRES HANGING IN MASTER CLOSET |