Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/13/2007 | FRAMING | Approved | IVRS - Inspection :* | |
| 07/12/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PRIOR INSPECTION 2) COMPLETE STUCCO MESH AT BACK OF HOUSE |
|
| 07/11/2007 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE DETAIL 501 PER PLAN AT BEDROOM CLOSET/GARAGE SHEAR 2) SEAL ALL HOLES AT MOISTURE BARRIER 3) ADD STUDS IN SHEAVE TO PICK UP NAILING AT ENDS OF SHEARPANELS 4) ADD BANG PLATE AT ROMEX BY HOMERUNS AND BEDROOMS 5) PROVIDE A COMPLETE TEST ON ALL DWV |