Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T07CM01727
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2007 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
10/04/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ITEM 1, 2, & 3 FROM 9/26.07 NOT DONE |
|
09/26/2007 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) HAND RAIL MUST EXTEND TO RISER OF FIRST STEP 2) HAND RAIL MUST BE CONTINOUS FROM FIRST RISER TO TOP RISER 3) STAIR HANDRAIL MUST BE 34-38" ABOVE STAIR BULL NOSE ONE PLANE 4) CLOSET LIGHT MUST BE 12" HORIZONTALLY FROM SHELF MASTER CLOSET 5) YOU MUST PROVIDE LADDER ACCESS TO ROOF A/C EITHER HOLD OR SECURE TO BLDG 6) GFCI OUTLET MISSING AT KITCHEN COUNTER EAST END OUTLET MUST BE WITHIN 24" OF END COUNTER 7) BX/ARMOR FLEX CABLE IS UNGROUNDED. MUST BE METAL 8) NO RANGE ANTI-ELECTRIC BOX AT PENINSULA TILT |