Permit: T07CM01727

Parcel: 141093910


Addresses:

6434 E LACO WY


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T07CM01727

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/05/2007 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/03/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. 5/3 NOT COMPLIED WITH FRONT DECK KING STUDS. STRAPS CANNOT BE BENT. MUST BE STRAIGHT AND TIGHT REQUIRED AT 4FT O.C
2. PROVIDE DETAIL FOR SHORT PORCH BEAM SUPPORT
3. REAR PORCH AND DECK NOT CLIPPED
4. ENTRY HOLDDOWN NOT IN
5. FRONT SHEAR WALL NOT BLOCKED OR NAILED ABOVE ENTRY
6. REAR 2ND FLOOR PORCH 6X8 BEAM NOT SUPPORTED
07/02/2007 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) 5/3 NOT COMPLIED WITH THROUGHOUT
2) PROVIDE APPROVED DETAIL FOR REAR PORCH SHORT BEAM SUPPORT
3) REAR SHEAR NOT NAILED
4) ENTRY HOLDOWN NOT IN
5) HOUSE ROOF OK-REAR PORCHES NOT READY