Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: MECHANICAL - INTERMEDIATE
Permit Number - T07CM01698
Inspection Description - MECHANICAL - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2007 | MECHANICAL - INTERMEDIATE | Approved | IVRS - Inspection :* | |
10/11/2007 | MECHANICAL - INTERMEDIATE | Partial Approval | IVRS - Inspection :* OK TO INSULATE |
|
10/10/2007 | MECHANICAL - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* CANCELLED |
|
10/02/2007 | MECHANICAL - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* - PLANS * 2003 IECC REQUIRE R8 DUCT IN THE ATTIC - PLANS REQUIRE 1/2" THICK INSULATION ON REFER LINES - PROVIDE A SCREW IN DUCT CONNECTION TO EXHAUST FANS - REMOVE SCREENS FROM DRYER VENT T-TOPS - SUPPORT REFER LINES AT PENETRATION THRU PLATES - PROVIDE PRIMER ON ALL PVC FITTINGS |